本页暂无Chinese版本,以下为英文原文。 查看英文版 →
U0002 U0xxx · 网络通信(U) 中严重度
High Speed CAN Communication Bus Performance
The bus still works but with errors, retries or degraded signal quality. Far more common than a total bus failure and much harder to spot.
严重程度说明: 中——已影响行驶或排放,请本周内安排检修
你会注意到的故障现象
- Intermittent warning lamps
- Random module dropouts
- Faults that clear themselves
常见原因
按可能性从高到低排列——从最上面开始查。
- 1 Corroded or loose connector terminal
- 2 Aftermarket equipment teed into the bus
- 3 Water ingress in a junction connector
- 4 Marginal earth raising noise
如何排查
先做花钱最少、侵入最小的检查——大多数这类码不是零件问题。
- ✓ Check for recently fitted aftermarket equipment first — trackers, alarms and audio interfaces are frequent culprits.
- ✓ Wiggle the harness while watching for bus errors.
- ✓ Inspect junction connectors for moisture.
- ✓ Scope for ringing or a collapsed recessive level.
维修方案
- Remove or correctly interface aftermarket equipment
- Clean and reseat connectors
- Repair the affected wiring section
U0002 —— 常见问题
Why does it only happen in the rain? +
Water in a connector changes bus capacitance. Find the wet junction and seal it.
Can a tracker really break the bus? +
Yes. Anything teed into CAN without proper interfacing distorts the signal.